USAEQUIPMENT Inc <><
Home
ET20D - Endodontic
ET40D - Endodontic
ET20 - Endodontic
Diamond Coated 20mm Tip from Bend Angle

Used in a variety of endodontic procedures,
including the removal of dental pulp, retreatment,
retrieval of seperated instruments, identifying canal
openings and the removal of cements. Vista Dental
recommends usage of irrigation as a colling agent
when removing crowns and posts to avoid injury
20mm Tip from Bend Angle

Same geometry as the ET20D without the
diamond coating. This tip reacts less
aggressively and is not recommended for
cements.
Diamond Coated 40mm Tip from Bend Angle

Similar to the functionality of the ET20D, however is
more powerful for retreatments and removal of the
hardest cements. Vista Dental recommends usage of
irrigation as a cooling agent when removing crowns
and posts to avoid injury
ET40 - Endodontic
CT4 - Endodontic / Condensation Tip
CT7 - Endodontic / Condensation Tip
40mm Tip from Bend Angle

Same geometry as the ET40D without the diamond
coating, used for retreatments and removal of the
hardest cements. This tip reacts less aggressively
than the ET40D.
Medium Condensation Tip (Equivalent to the SO7
Tip)
General purpose condensation of single or multiple
gutta percha points in a preperly sized canal. Twice
the thickness of the CT4 throughout most of the tip
and more powerful than the CT4.
Thin Condensation Tip (Equivalent to the SO4 Tip)

Used for the condensation of a single gutta-percha
point in a properly sized canal.
PRT - Crown & Post Removal
S12/70 & S12/70 (D) - Apical Surgery
S12/90 & S12/90 (D) - Apical Surgery
 Picture


  coming


 soon
Crown & Post Removal Tip (Equivalent to the 5AE
Tip)

Used for ultrasonic loosening of crowns and posts
with irrigation. We recommend usage of irrigation as
a cooling agent when removing crowns and posts to
avoid injury .
Surgery Tip / 70° Angle

Generally used on anterior teeth. S12/70(D) features
a Diamond coating for extra durability and when
more abrassive power is needed during procedures.
Surgery Tip / 90° Angle

Generally used on anterior teeth. S12/90(D) features
a Diamond coating for extra durability and when
more abrassive power is needed during procedures
S13L & S13L (D) - Apical Surgery
34 - Crown Removal
S13R & S13R
• Apical Surgery Tip
• Contact with light pressure in long axis of root
• Slight angle to the right
• D refers to diamond coating
• Power setting: S13R: 8-14 S13RD: 7 – 9
Surgery Tip / Left Angle

Generally used on posterior teeth. S13L(D) features
a Diamond coating for extra durability and when
more abrassive power is needed during procedures
• Endodontic Tip
• Crown Removal
• Power range: 1 – 10
35A - Crown Cementing
34S - Crown Removal
35 - Crown Removal
• Endodontic Tip
• Condensation of amalgam
• Power range: 1 – 5
• Endodontic Tip
• Crown Removal
• Power range: 1 – 10
• Endodontic Tip
• Thixotropic cementing of crowns and inlays
• Power range: 1 – 5
35B - Crown Cementing
35C - Crown Cementing
• Endodontic Tip
• Thixotropic cementing of crowns and inlays
• Power range: 1 – 5
• Endodontic Tip
• Thixotropic cementing of crowns and inlays
• Power range: 1 – 5